Our Data Centers

Pick from one of our 5 different data center locations to have your services hosted in.

Select Data Center Location to View Details

SolaDrive Data Center

Los Angeles, California

Services Offered in this Data Center

.
VPS Servers
.
Dedicated Servers
.
Colocation
Los Angeles, CA
Data Center Name

LA Telecom Center

Speed Test

Los Angeles, California

.
Ping

66.248.240.55
216.144.236.177

Download 100MB Test File
Data Center Location

Data Center Address

530 West 6th Street Los Angeles, California

Location

From our Los Angeles location, we utilize the L.A. Telecom Center, which is located right across the One Wilshire (1 Wilshire) building at 624 South Grand, aka "the world's most connected data center building," due to its large connection of fiber from various backbones and internet peers. We have over 400 private fiber lines connected from their direct backbones, making it an extremely desirable network to be on, without the extremely expensive costs. It also happens to be a Tier-IV data center as well: an extremely reliable place to be hosted.

  • 163,600 square foot building fully dedicated to data center services.
  • Direct conduit of less than 500 feet connectivity to One Wilshire.
  • Complete renovation conducted in 1998.
  • 24/7 on-site engineers to support building systems and provide client service.
  • Power Systems

    Power Systems

    • 6000 amps, 277/480 Volt, 3-phase, and 4-wire electrical service.
    • Each suite equipped with 2 x 150KvA UPS Battery Backup Units.
    • Redundant UPS ensures 30 minutes of battery life at full capacity until generators can take over.
    • 1200Amps 480v Input Power per suite.
    • All suites backed by 3 x 2000Kw Caterpillar Generators.
    • Generators have separate diesel tanks with refuel contracts.
  • Temperature Control

    Temperature Control

    • Liebert System 3 HVAC Units.
    • Data center floor temperature at 65 ° F more or less 2 ° F.
    • Dry pipe fire suppression with pre-activation.
    • 500 Ton redundant HVAC central plant, consisting of two-250 Ton Cooling Towers.
  • Building Security

    Building Security

    • 24/7 manned security with regular patrols from LAPD.
    • Biometric palm scan authentication access requirement.
    • Substantial amount of surveillance cameras with offsite backup.
    • Every suite secured by keycard authorized entry
    • Guests are required to have background check and be accompanied by onsite staff
  • Network Connectivity

    Network

    • Redundant Brocade XMR 4000 Edge Routing.
    • Full router redundancy - 3 switch fabrics, multiple line-cards, 2x management modules.
    • Cisco Catalyst Distribution Switches (N+1 redundant).
    • Cisco Catalyst 2950 and 3750 access switches (redundancy).
    • Connections to the One Wilshire "meet me Room" are provided through the second floor Network Access Center (NAC).
SolaDrive Data Center

Buffalo, New York

Services Offered in this Data Center

.
VPS Servers
.
Dedicated Servers
.
Colocation
Buffalo, NY
Data Center Name

Main Place Tower

Speed Test

Buffalo, New York

.
Ping

192.3.180.103
66.248.241.2
45.42.140.2

Download 100MB Test File
Data Center Location

Data Center Address

350 Main St Buffalo, NY 14202

Location & Building

Our Buffalo, NY facility is strategically located near the Niagara Falls, allowing us to have 90% hydro-electric, green energy and leave a very small carbon footprint. This data center also happens to be our main facility. We have located ourselves in the very large ColoCrossing data center having over 5k sq/ft of suite space to ourselves. We use this facility for many reasons. Such as it being located on the country’s major backbones, 2ms from NYC financials and all major ISP backbones, Tier-3 SAS70 Type II certified facility, and being nearly 100% green!

Our network is fully redundant native 10GE, which consists of Level3, Telia, XO, Verizon, AT&T, Centurylink, Fibertech, TW Telecom, and Time Warner Cable. Having such a diverse premium tier of peering allows our customers to have the very best latency across the country and Europe.
  • Located on 8th Floor in Main Place Tower.
  • 270,490(sq ft) gross - 23,000(sq ft) data center.
  • 11 miles from Buffalo International Airport.
  • SAS 70 Type II Compliant.
  • Minimum N+1 on all systems.
  • Data Center Commissioned in 2009.
  • Power Systems

    Power Systems

    • 2,000kW of critical load capacity.
    • 210 watts/sqft, up to 12kW/cabinet supported.
    • 34.5kV of Power Voltage.
    • 2 Power Utility Feeders & 4 Power Transformers.
    • 3 x 1,300kW rotary UPS systems.
    • 2 x 10,000kW Cat diesel generator systems with 10,000 gallons of onsite diesel fuel.
  • Temperature Control

    Temperature Control

    • Laser-based Very Early Fire/Smoke Detection. Pre-action zoned dry-pipe system.
    • Data center floor temperature at 65° F with no more than 2 degree difference.
    • 130 Tons total cooling capacity
    • 6x20 Ton Liebert Air Handlers
    • Hot/Cold aisle design with raise floors along with building-wide chilled water loop.
  • Building Security

    Building Security

    • 24/7 manned security with regular patrols from local authorities.
    • Bullet-resistant protection at security check-in level III walls and doors.
    • Dual-factor authentication system (keycard + biometrics).
    • Emergency Intruder Alarm System.
    • Camera surveillance archived onsite and offsite.
  • Network

    Network

    • Redundant network design to accommodate 100% SLA.
    • 2 diverse fiber vaults for redundant entry.
    • Cisco Catalyst Distribution Switches (N+1 redundant).
    • Automatic DDoS detection and mitigation systems to avoid any disruption in service.
    • Low latency and high throughput network across North America and Europe.
SolaDrive Data Center

Seattle, Washington

Services Offered in this Data Center

.
VPS Servers
.
Dedicated Servers
.
Colocation
Seattle, WA
Data Center Name

Westin Building Exchange

Speed Test

Seattle, Washington

.
Ping

199.231.241.88
66.248.243.2

Download 100MB Test File
Data Center Location

Data Center Address

2001 6th Ave Suite #400 Seattle, WA 98121

Location & Building

Our smaller presence in Seattle, WA facility is by no means of skimping quality. We are located right within the well known Seattle Westin Building. Standing at 34 floors and named carrier hotel for the Pacific Northwest there is no better place to be located in Seattle for any internet or hosting based requirements.

Along with extensive fiber and copper Meet-Me room, the Westin Building offers neutral connectivity points to Asian, Canadian, European and American network service providers. It also provides access to numerous other networks via the Seattle Internet Exchange. There is no better place to be located in the Seattle area for connectivity and reliability.

  • Facility is Designed With 2N Redundancy.
  • 400,000 SF (sq ft) Gross - Data Center Space.
  • Hub of the Pacific Northwest.
  • Tier 4 Rated Data Center.
  • Built to Seismic Zone 3 Standards.
  • Typical structural capacity of 150 lbs/SF or 1500 lb cabinets.
  • Power Systems

    Power Systems

    • Multiple 13.5 kV feeds.
    • Multiple transformer vaults – 480V 3 Phase.
    • 2N redundancy facility wide.
    • Canara battery monitoring system.
    • 17 diesel generators, totaling 19.5 MW.
    • Redundant AC/DC UPS power.
  • Temperature Control

    Temperature Control

    • Five diverse cooling towers.
    • N+1 redundancy on all cooling systems.
    • Onsite reserve water tanks.
    • Hot/Cold aisle design with raise floors.
  • Building Security

    Building Security

    • 24x7 onsite dedicated security staff.
    • 24x7 secure/monitored site access.
    • CCTV monitoring and recording.
    • Individual locking cabinets for Colocation clients.
    • Sign in and identification required.
  • Network Connectivity

    Network

    • Carrier Neutral Facility with more than 200 carriers.
    • Diverse Premier Fiber and Copper Meet-Me Rooms.
    • Multiple fully diverse underground main points of entry.
    • Fully redundant network with no single point of failure.
    • Low latency and high throughput network across North America, Asian and Europe countries.
SolaDrive Data Center

Coventry, UK

Services Offered in this Data Center

.
VPS Servers
.
Dedicated Servers
.
Colocation
Coventry, UK
Data Center Name

Pulsant Data Center

Speed Test

Coventry, UK

.
Ping

78.157.209.195

Download 100MB Test File
Data Center Location

Data Center Address

West Park Ind Est 211 Torrington Avenue Coventry, UK CV4 9HN

Location & Building

In our European location we privately own a data center site in Coventry, U.K. The secure facility is equipped with n+1 UPS systems, diesel generator backup power, and the latest technology in n+1 evaporative cooling systems. Data center is manned by our competent staff 24/7 and has an advanced network health monitoring system that responds automatically to hardware failures, DDoS attacks and more. This is a premium location for reliability and performance.

  • 2 story building, raised floors, hot/cold aisles.
  • 4500sq/ft of privately owned rack space.
  • Concrete, brick, and steel.
  • Sits right on main backbones in UK.
  • Privately Owned Suite in DC.
  • SAS 70 compliant.
  • Power Systems

    Power Systems

    • Two redundant high voltage power systems, from separate power grids.
    • 2 x 2.5MVA 11kV Generators.
    • Two redundant UPS, floor by floor with battery backup.
    • A + B power to individual servers upon request.
    • Generators have separate diesel tanks stored in basement.
  • Temperature Control

    Temperature Control

    • Latest technology n+1 evaporative cooling system.
    • 850mm raised floor design to provide the most efficient cooling.
    • Hot aisle/cold aisle zone design.
    • Free cooling operation in winter.
    • 2 x 2.7MW chillers.
    • Room Air Conditioning Units provide a down stream chilled water system.
  • Building Security

    Building Security

    • Swipe identification card & visual entry check by manned security.
    • Keycard access and video facial recognition surveillance.
    • Monitoring and secure single-person point of entry, which is physically guarded 24/7 and the presence of integrated surveillance.
    • Full Interior and Exterior CCTV Coverage and Recording.
  • Network

    Network

    • 100Gbps onsite connectivity.
    • Diverse fiber backhaul to docklands.
    • Multiple ranges of fiber providers sitting miles from DC.
    • Premium Cisco hardware with redundant topology.
    • Automatic DDoS detection and mitigation systems to avoid any disruption in service.
SolaDrive Data Center

Singapore

Services Offered in this Data Center

.
VPS Servers
.
Dedicated Servers
.
Colocation
Coventry, UK
Data Center Name

Singapore IBX Data Center

Speed Test

Ayer Rajah, Singapore

.
Ping

45.42.143.98

Download 100MB Test File
Data Center Location

Data Center Address

20 Ayer Rajah Crescent Ayer Rajah Industrial Park 139964, Singapore

Location & Building

In partnership with Equinix, Soladrive now has a presence in Singapore. Our Singapore-based data center is located within a heavily connected 9-story building in Ayer Rajah Industrial Park. Ayer Rajah is the business hub of more than 600 companies looking for data solutions and is centrally placed to access key nations around the world.

Our building houses one of the globe’s top internet peering exchanges. It has completed the Threat and Vulnerability Risk Assessment (TRVA) as per MAS guidelines. Additionally, it features a Solution Validation Center, which helps companies optimize IT investments and mitigate risks by comprehensively testing products before deployment. There is no better place to set up shop than this South East Asia facility.

  • Located within a 9-story building in Ayer Rajah Industrial Park.
  • Raised 208 psf floor with a 10 to 12.5 kN/m2 floor load.
  • 4.9m slab-to-ceiling height.
  • Access to 210 network carriers for unmatched customer reach.
  • MAS Compliant.
  • Offers access to a fully equipped Solution Validation Center.
  • Power Systems

    Power Systems

    • 1.2 - 4kVA electrical capacity.
    • 2 x 22kV Power Utility Feeders.
    • 10 x 3 MVA (N+1) Power Transformers.
    • 2N UPS Configuration.
    • 2N UPS Redundancy.
    • 8 x 1,375 kVA and 3 x 2,000 kVA standby diesel generators.
    • N+1 Standby Power Redundancy.
  • Temperature Control

    Temperature Control

    • 1.2 - 4kVA cooling capacity per cabinet.
    • Air-Cooled Centrifugal Chillers – 3 x 300 RT + 5 x 350 RT (N+1).
    • Water-Cooled Centrifugal Chillers – 4 x 600 RT + 1 x 300 RT (N+1).
    • Computer Room Air Conditioners – N+25%.
    • Cooling redundancy of N+1 (on chillers) and N+25% (on CRAC units).
    • VIEW, VESDA, and FM-200 fire suppression systems.
    • Pre-action dry pipe sprinklers.
  • Building Security

    Building Security

    • 24/7 onsite security officers.
    • Man-trap entry.
    • Biometric readers in common areas.
    • A combination of biometrics, PIN, and Card readers in sensitive areas.
    • CCTV surveillance with a 30-day retention.
    • Motion detection alarm system.
  • Network

    Network

    • Cat5e/6, COAX and Fiber cross-connects.
    • Fast Ethernet, Gigabit Ethernet, and 10Gigabit Ethernet.
    • High-speed fiber connectivity extends choice and reach for carrier and network availability.
    • Central switch for public and private peering.
    • Automated network provisioning, multi-homing, and billing.